HT250D Headspace & Liquid Autosampler in one unit

Product Information:

Two Autosamplers - One Unit!

The HT250D is a single unit combining Static Headspace analysis with traditional liquid sample injection at a price not much more than the headspace unit alone!

Consider that the HT250D is compatible with most GC and GC/MS systems, both present and past, and you have a truly remarkable development in GC autosampling that can save you time and money, increase analysis flexibility and save older GCs from redundancy.

Changing from Liquid to Headspace is as simple as changing the sample tray, syringe and vial sensor - about 5 minutes in total without the need to remove the sampler from the GC.

The HT250D effectively combines the operation of the HT200H Headspace autosampler with the HT300A Liquid autosampler in a single unit of the same dimensions as the HT200H. The system is supplied with a conversion kit, allowing the user to switch from headspace to liquid operation.

Headspace Operation

The system is supplied with a heated syringe to extract headspace samples from the 6 position orbital oven/shaker. No transfer lines are required and the unit mounts directly on the GC thus reducing bench space requirements. Operation is via the simple keypad or by HT-COMSoft software. Up to 40, 20ml or 10ml headspace vials may be stored in the standard tray.

Key Features:

  • No transfer lines means no sample crossover
  • Rotating head design leaves injection port free for manual injection
  • Progressive sample transfer means samples always ready when previous run completed
  • May be configured for left or right operation
  • Gas flush of syringe between injections

Liquid Autosampler Conversion

The user can simply change the operation of the autosampler from headspace to liquid at any time. A conversion kit is supplied which includes a 110 position sample tray for 2ml vials, wash and waste vials, 10µl syringe kit and sensor for 2ml vials. Just one simple tool (supplied) is required for the conversion which takes around 5 minutes to complete with the autosampler in situ.

The autosampler automatically detects the tray type and the on-board software switches modes from headspace to liquid.

Liquid Sampler Operation

Up to 110 samples may be processed as single or batch injections using one or more analysis methods. Any 12x32mm vial may be used with any cap type. All parameters from the sampling depth through to the injection speed, depth and dwell times may be programmed through the front panel or via the HT-COMSoft WindowsTM software

The automatic injection sequence may have up to 15 steps which can be programmed to include:

  • First sample of group
  • Last sample of group
  • Analytical method
  • Number of injections for each sample
  • Pre- and Post-washing solvent position
  • Internal Standard position (if used)

Key Features:

  • No transfer lines means no sample crossover
  • Syringe may be washed with solvent or sample
  • Injections may be made on two columns (high throughput and confirmation mode)
  • Rotating head design leaves injection port free for manual injection
  • Internal standard sampling
  • Memory stores 10 different methods
  • Variable fill speed allows for wide range of sample viscosities
  • Sampling system eliminates air bubbles
  • Programmable sampling and injection speed


Specifications:
HEADSPACE OPERATION
Shaking Method: Orbital
Incubation Oven: 6 position
Syringe Size: 2.5ml
Tray Capacity: 40 Vials, 10 or 20ml
Cleaning System: Nitrogen
GC Compatibility:
Agilent/HP 4890
Agilent/HP 5890
Agilent/HP 6850A
Agilent/HP 6890
Carlo Erba 5300 Mega
Carlo Erba 8000
Carlo Erba 8000 Top
Carlo Erba 8500 Mega 2
Chemito 1000
Chrompack CP9001/2
Dani 8610/8500
Donam DS6200
Gow Mac*
Kristallux 4000M
Meta Chrom*
Perkin Elmer XL
Shimadzu GC-14A/B/C
Shimadzu GC-17A
Shimadzu GC-2010
Shimadzu GC-2014
SRI 8610*
Trace SX
Varian 3300/3400
Varian 3800
Varian 3900
Younglin*

* Only if specified when ordering the GC
If your GC is not listed it may still be compatible. Please contact us for details.
Conditioning
Oven Temperature: 40 - 150°C
Time: 0 - 23h 59m
Progressive Increase: 0 - 23h 59m
Shaking Cycles On/Off: 0 - 99mins
Sampling
Syringe Temperature: 40 - 150°C
Pre-fill Volume: Steps of 0.01ml
Pull Up Strokes: Up to 15 Strokes
Equilibrium Delay: Up to 60secs
Sampling Volume: Steps of 0.01ml
Filling Speed: 0.1 - 100ml/min
Injection
Sampling Repeats: Up to 15
Waiting Time between Samples: 1 - 99secs
Injection Speed: 0.1 - 100ml/min
Waiting Time
(before and after injection):
1 - 99secs
LIQUID OPERATION
Syringe Sizes: 1, 10, 25, 50 & 100µl
Tray Capacity: 110 Vials, 2 or 2.5ml
40 Vials, 10ml
Sample Volume: Steps of 0.1µl
Air Volume: Steps of 0.1µl
Aspirating Speed: 0.1 - 100µl/sec
Needle Washing: Up to 15 Strokes
Air Bubble Removing: Up to 15 Strokes
Viscosity Time: 1 - 60secs
Injection
Injection Speed: 0.1 - 100µl/sec
Waiting Time
(before and after inject):
1 - 60secs
Injection Depth: Variable
Internal Standard Technique
IS Volume: Steps of 0.1µl
Air Gap Volume: Steps of 0.1µl
Mode: 1 or 2 air gaps
GENERAL
Control
Electrical Control: RS232 and TTL
Physical Characteristics
Dimensions (W x H x D): 420 x 520 x 400mm
Mass: 11.5kg

Price: € 15400.00